Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 8.894
Filtrar
1.
Radiat Oncol ; 19(1): 49, 2024 Apr 16.
Artigo em Inglês | MEDLINE | ID: mdl-38627747

RESUMO

OBJECTIVE: This study evaluates various craniospinal irradiation (CSI) techniques used in Turkish centers to understand their advantages, disadvantages and overall effectiveness, with a focus on enhancing dose distribution. METHODS: Anonymized CT scans of adult and pediatric patients, alongside target volumes and organ-at-risk (OAR) structures, were shared with 25 local radiotherapy centers. They were tasked to develop optimal treatment plans delivering 36 Gy in 20 fractions with 95% PTV coverage, while minimizing OAR exposure. The same CT data was sent to a US proton therapy center for comparison. Various planning systems and treatment techniques (3D conformal RT, IMRT, VMAT, tomotherapy) were utilized. Elekta Proknow software was used to analyze parameters, assess dose distributions, mean doses, conformity index (CI), and homogeneity index (HI) for both target volumes and OARs. Comparisons were made against proton therapy. RESULTS: All techniques consistently achieved excellent PTV coverage (V95 > 98%) for both adult and pediatric patients. Tomotherapy closely approached ideal Dmean doses for all PTVs, while 3D-CRT had higher Dmean for PTV_brain. Tomotherapy excelled in CI and HI for PTVs. IMRT resulted in lower pediatric heart, kidney, parotid, and eye doses, while 3D-CRT achieved the lowest adult lung doses. Tomotherapy approached proton therapy doses for adult kidneys and thyroid, while IMRT excelled for adult heart, kidney, parotid, esophagus, and eyes. CONCLUSION: Modern radiotherapy techniques offer improved target coverage and OAR protection. However, 3D techniques are continued to be used for CSI. Notably, proton therapy stands out as the most efficient approach, closely followed by Tomotherapy in terms of achieving superior target coverage and OAR protection.


Assuntos
Radiação Cranioespinal , Radioterapia Conformacional , Radioterapia de Intensidade Modulada , Adulto , Humanos , Criança , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/métodos , Radiação Cranioespinal/métodos , Turquia , Radioterapia Conformacional/métodos , Radioterapia de Intensidade Modulada/métodos
2.
Sci Rep ; 14(1): 7134, 2024 03 26.
Artigo em Inglês | MEDLINE | ID: mdl-38532018

RESUMO

We aimed to investigate the deliverability of dynamic conformal arc therapy (DCAT) by gantry wobble owing to the intrinsic inter-segment break of the Elekta linear accelerator (LINAC) and its adverse influence on the dose to the patient. The deliverability of DCAT was evaluated according to the plan parameters, which affect the gantry rotation speed and resultant positional inaccuracies; the deliverability according to the number of control points and dose rates was investigated by using treatment machine log files and dosimetry devices, respectively. A non-negligible degradation in DCAT deliverability due to gantry wobble was observed in both the treatment machine log files and dosimetry devices. The resulting dose-delivery error occurred below a certain number of control points or above a certain dose rate. Dose simulations in the patient domain showed a similar impact on deteriorated deliverability. For targets located primarily in the isocenter, the dose differences were negligible, whereas for organs at risk located mainly off-isocenter, the dose differences were significant up to - 8.77%. To ensure safe and accurate radiotherapy, optimal plan parameters should be selected, and gantry angle-specific validations should be conducted before treatment.


Assuntos
Radioterapia Conformacional , Radioterapia de Intensidade Modulada , Humanos , Dosagem Radioterapêutica , Radioterapia Conformacional/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Aceleradores de Partículas , Radiometria/métodos , Radioterapia de Intensidade Modulada/métodos
3.
JCO Glob Oncol ; 10: e2300478, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38484193

RESUMO

PURPOSE: The PARCER trial provided level I evidence for image-guided intensity-modulated radiation therapy (IG-IMRT) in patients with cervical cancer. Further information regarding long-term financial impact is imperative for adoption into the National Cancer Grid of India cervical cancer resource-stratified guidelines. METHODS: Patient data from the PARCER trial were analyzed to evaluate the cost implications of transitioning to IG-IMRT. Lacking differences in outcomes between the three-dimensional conformal radiation (3D-CRT) and IG-IMRT, differences in treatment costs, adverse event incidence, and toxicity management costs were examined. The overall financial impact was estimated by adding the treatment costs, toxicity management, and wage loss. This was extrapolated nationally to determine if a transition to IG-IMRT would be feasible for the Indian health care system. RESULTS: Of the 300 patients in the PARCER trial, 93 faced grades ≥2 adverse events (3D-CRT = 59, IG-IMRT = 34). Patients in the 3D-CRT and IG-IMRT arms spent an average of 2.39 years and 1.96 years in toxicity, respectively. The average toxicity management and the yearly financial impact per patient were, respectively, 1.50 and 1.44 times higher for 3D-CRT patients compared with IG-IMRT patients. Extrapolation to the national level showed that treatment with 3D-CRT led to a 2.88 times higher cost ratio when compared with treatment with IG-IMRT. CONCLUSION: Although the initial costs of IG-IMRT are high, on the basis of longitudinal data, it is financially inefficient to treat with 3D-CRT. Resource-stratified guidelines should include longitudinal health intervention costs rather than solely initial costs for policy decisions to implement advanced radiation technology.


Assuntos
Radioterapia Conformacional , Radioterapia de Intensidade Modulada , Neoplasias do Colo do Útero , Feminino , Humanos , Radioterapia de Intensidade Modulada/efeitos adversos , Radioterapia de Intensidade Modulada/métodos , Neoplasias do Colo do Útero/radioterapia , Países em Desenvolvimento , Radioterapia Conformacional/efeitos adversos , Radioterapia Conformacional/métodos , Dosagem Radioterapêutica
4.
J Cancer Res Ther ; 20(1): 327-332, 2024 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-38554342

RESUMO

BACKGROUND: The purpose of this study was to evaluate the dosimetric benefits of carotid-sparing IMRT (intensity-modulated radiation therapy) over 3DCRT (three-dimensional conformal radiation therapy) in early glottic cancer patients. MATERIAL AND METHODS: Ten patients with histologically proven early-stage squamous cell cancer of glottis (T1N0), treated with definitive radiotherapy, were selected retrospectively for the dosimetric analysis. Patients were originally treated with 3DCRT technique. For comparison purpose, IMRT plans were generated for each patient. Dosimetric comparison was done between two techniques (IMRT and 3DCRT) in terms of PTV (planning target volume) coverage, HI (homogeneity index), CI (conformity index), and doses to right carotid artery, left carotid artery, and spinal cord. RESULTS: V95% for the PTV was higher in IMRT plans (98.26%) as compared to 3DCRT plans (95.12%) (P-value <0.001), whereas V105% for PTV was significantly higher in 3DCRT plans (16.77%) as compared to IMRT plans (0.32%) (P-value 0.11). In terms of both HI and CI, IMRT plans showed better conformity as compared to 3DCRT plans, with statistically significant difference. Both right and left carotid arteries' average mean and maximum doses were significantly lower in IMRT plans as compared to 3DCRT plans (P-value <0.001). IMRT plans resulted in significant carotid-sparing as compared to 3DCRT plans in terms of V35 and V50 (P-value <0.001). CONCLUSION: Carotid-sparing IMRT resulted in better PTV coverage and lower carotid artery dose as compared to 3DCRT in early glottic cancer patients.


Assuntos
Neoplasias Laríngeas , Radioterapia Conformacional , Radioterapia de Intensidade Modulada , Humanos , Radioterapia de Intensidade Modulada/métodos , Neoplasias Laríngeas/radioterapia , Estudos Retrospectivos , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia Conformacional/métodos , Artérias Carótidas , Glote , Dosagem Radioterapêutica
5.
Phys Med ; 120: 103332, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38518627

RESUMO

As part of translational research projects, mice may be irradiated on radiobiology platforms such as the one at the ARRONAX cyclotron. Generally, these platforms do not feature an integrated imaging system. Moreover, in the context of ultra-high dose-rate radiotherapy (FLASH-RT), treatment planning should consider potential changes in the beam characteristics and internal movements in the animal. A patient-like set-up and methodology has been implemented to ensure target coverage during conformal irradiations of the brain, lungs and intestines. In addition, respiratory cycle amplitudes were quantified by fluoroscopic acquisitions on a mouse, to ensure organ coverage and to assess the impact of respiration during FLASH-RT using the 4D digital phantom MOBY. Furthermore, beam incidence direction was studied from mice µCBCT and Monte Carlo simulations. Finally,in vivodosimetry with dose-rate independent radiochromic films (OC-1) and their LET dependency were investigated. The immobilization system ensures that the animal is held in a safe and suitable position. The geometrical evaluation of organ coverage, after the addition of the margins around the organs, was satisfactory. Moreover, no measured differences were found between CONV and FLASH beams enabling a single model of the beamline for all planning studies. Finally, the LET-dependency of the OC-1 film was determined and experimentally verified with phantoms, as well as the feasibility of using these filmsin vivoto validate the targeting. The methodology developed ensures accurate and reproducible preclinical irradiations in CONV and FLASH-RT without in-room image guidance in terms of positioning, dose calculation andin vivodosimetry.


Assuntos
Terapia com Prótons , Radioterapia Conformacional , Humanos , Camundongos , Animais , Prótons , Terapia com Prótons/métodos , Pulmão , Imagens de Fantasmas , Método de Monte Carlo , Carmustina , Etoposídeo , Dosagem Radioterapêutica
6.
Phys Med ; 120: 103343, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38547546

RESUMO

PURPOSE: Stereotactic radiotherapy (SRT) has transformed cancer treatment, especially for brain metastases. Ensuring accurate SRT delivery is crucial, with the Winston-Lutz test being an important quality control tool. Off-axis Winston-Lutz (OAWL) tests are designed for accuracy assessment, but most are limited to fixed angles and hampered by local-field shifts caused by suboptimal Multi-Leaf Collimator (MLC) positioning. This study introduces a new OAWL approach for quality control in multi-brain-metastasis SRT. Utilizing cine Electronic Portal Imaging Device (EPID) images, it can be used with dynamic conformal arc (DCA) therapy. However, dynamic OAWL (DOAWL) is prone to more local-field shifts due to dynamic MLC movements. A two-step DOAWL is proposed: step 1 calculates local-field shifts using dynamic MLC movements in the beam-eye view data from the Treatment Planning System (TPS), while step 2 processes cine EPID images with an OAWL algorithm to isolate true deviations. METHODS: Validation involved an anthropomorphic head phantom with metallic ball-bearings, Varian TrueBeam STx accelerator delivering six coplanar/non-coplanar DCA beams, cine EPID, and ImageJ's OAWL analysis algorithm. RESULTS: Inherent local-field shifts ranged from 0.11 to 0.49 mm; corrected mean/max EPID-measured displacement was 0.34/1.03 mm. Few points exceeded 0.75/1.0-mm thresholds. CONCLUSIONS: This two-step DOAWL test merges cine-EPID acquisitions, DCA, OAWL, and advanced analysis and offers effective quality control for multi-brain-metastasis SRT. Its routine implementation may also improve physicist knowledge of the treatment precision of their machines.


Assuntos
Neoplasias Encefálicas , Radiocirurgia , Radioterapia Conformacional , Radioterapia de Intensidade Modulada , Humanos , Radioterapia Conformacional/métodos , Diagnóstico por Imagem , Imagens de Fantasmas , Controle de Qualidade , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador
7.
Radiat Oncol ; 19(1): 21, 2024 Feb 13.
Artigo em Inglês | MEDLINE | ID: mdl-38347554

RESUMO

BACKGROUND: The dosimetric effect of setup uncertainty and tissue deformations in left-sided whole-breast irradiation with complementary surface-guided radiotherapy (SGRT) and cone-beam computed tomography (CBCT) setup was evaluated. METHOD: Treatment courses of 40.05 Gy prescribed dose in 15 fractions were simulated for 29 patients by calculating the dose on deformed CT images, that were based on daily CBCT images, and deforming and accumulating the dose onto the planning CT image. Variability in clinical target volume (CTV) position and shape was assessed as the 95% Hausdorff distance (HD95) between the planning CTV and deformed CTV structures. DVH metrics were evaluated between the planned and simulated cumulative dose distributions using two treatment techniques: tangential volumetric modulated arc therapy (tVMAT) and conventional 3D-conformal radiotherapy (3D-CRT). RESULTS: Based on the HD95 values, the variations in CTV shape and position were enclosed by the 5 mm CTV-PTV margin in 85% of treatment fractions using complementary CBCT and SGRT setup. A residual error of 8.6 mm was observed between the initial SGRT setup and CBCT setup. The median CTV V95% coverage was 98.1% (range 93.1-99.8%) with tVMAT and 98.2% (range 84.5-99.7%) with 3D-CRT techniques with CBCT setup. With the initial SGRT-only setup, the corresponding coverages were 96.3% (range 92.6-99.4%) and 96.6% (range 84.2-99.4%), respectively. However, a considerable bias in vertical residual error between initial SGRT setup and CBCT setup was observed. Clinically relevant changes between the planned and cumulative doses to organs-at-risk (OARs) were not observed. CONCLUSIONS: The CTV-to-PTV margin should not be reduced below 5 mm even with daily CBCT setup. Both tVMAT and 3D-CRT techniques were robust in terms of dose coverage to the target and OARs. Based on the shifts between setup methods, CBCT setup is recommended as a complementary method with SGRT.


Assuntos
Radioterapia Conformacional , Radioterapia Guiada por Imagem , Radioterapia de Intensidade Modulada , Tomografia Computadorizada de Feixe Cônico Espiral , Humanos , Radioterapia de Intensidade Modulada/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia Guiada por Imagem/métodos , Dosagem Radioterapêutica , Tomografia Computadorizada de Feixe Cônico/métodos
8.
PLoS One ; 19(2): e0297997, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38363756

RESUMO

BACKGROUND: Radiotherapy plays a key role as an adjuvant treatment in pediatric Wilm's tumor, improving both survival and quality of life. The success of radiotherapy depends on the precise delivery of radiation dose to the tumor while sparing radiosensitive structures in the vicinity of the tumor. Pediatric patients pose unique challenges in achieving accurate radiotherapy delivery due to their inability to understand instructions and the high radiosensitivity of their tissues. Thus, it is important to determine the optimum geometric verification strategy that will ensure accurate delivery of the prescribed target as specified in the patient's treatment plan. PURPOSE: To evaluate the performance of an offline geometric correction strategy in ensuring accuracy and reproducibility during radiotherapy delivery in Wilm's tumor patients. MATERIAL AND METHODS: The extended no-action level offline correction strategy was applied in the radiotherapy delivery of 45 Wilm's tumor patients. Gross errors from the first three fractions were used to calculate the mean errors which were then applied as offline correction factors. Mean errors among different groups were compared using a two-way analysis of variance (ANOVA) and Dunnett's pairwise comparisons. All statistical analyses and data visualization were performed using GraphPad Prism version 7 (Insight Partners, GraphPad Holdings, LLC). RESULTS: A total of 45 patients were included in the study. In all three orthogonal directions, the recorded gross errors were significantly lower after the application of the systematic error corrections. Random errors were significantly larger in the longitudinal direction compared to lateral (mean difference = 0.28, p = 0.036) and vertical directions (mean difference = 0.37 cm, p = 0.003). Patients' age was a significant predictor of random errors whereby the magnitude of random error decreased with increasing age. CONCLUSION: This study shows that the offline correction strategy used is effective in ensuring the accuracy of radiotherapy delivery in pediatric Wilm's tumor patients.


Assuntos
Neoplasias Renais , Radioterapia Conformacional , Tumor de Wilms , Humanos , Criança , Reprodutibilidade dos Testes , Qualidade de Vida , Planejamento da Radioterapia Assistida por Computador , Neoplasias Renais/radioterapia
9.
In Vivo ; 38(2): 819-825, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38418123

RESUMO

BACKGROUND/AIM: Radiotherapy (RT) outcomes are generally reported based on stage, patient background, and concomitant chemotherapy. This study aimed to investigate the effects of the prescribed dose to gross tumor volume (GTV) and the calculation algorithm on local control in definitive RT for head and neck (H&N) cancers using follow-up images after RT. PATIENTS AND METHODS: This study included 154 patients with H&N cancers treated by Volumetric Modulated Arc Therapy at the Kobe City Medical Center General Hospital. Patients were classified into those receiving definitive RT (70 Gy of irradiation) and those not receiving it. Follow-up images were used to categorize the patients into the responders and non-responders groups. In the non-responders group, follow-up images were imported into the treatment planning system, and the contours of the residual or recurrent areas (local failure) were extracted and fused with computed tomography-simulated images for treatment planning. Dose evaluation parameters included maximum dose, dose administered to 1% of the volume, dose administered to 50% of the volume, dose administered to 99% of the volume (D99%), and minimum dose (Dmin) administered to the GTV. The doses to the GTV were compared between responders and non-responders. RESULTS: D99% exhibited significant differences between local failure and responders and between local failure and non-responders. Dmin showed significant differences between responders and non-responders and between responders and local failure. CONCLUSION: This study emphasizes the importance of verifying dose distribution in all slices of treatment planning, highlighting the need for precise assessment of the dose to the GTV in head and neck cancers.


Assuntos
Neoplasias de Cabeça e Pescoço , Radioterapia Conformacional , Radioterapia de Intensidade Modulada , Humanos , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/métodos , Neoplasias de Cabeça e Pescoço/radioterapia , Radioterapia Conformacional/métodos , Radioterapia de Intensidade Modulada/métodos
10.
Anticancer Res ; 44(2): 687-694, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38307577

RESUMO

BACKGROUND/AIM: The present study investigated the effect of respiratory motion on planned radiotherapy (RT) dose for gastric mucosa-associated lymphoid tissue (MALT) lymphoma using four-dimensional dose (4D-dose) accumulation. PATIENTS AND METHODS: 4D-computed tomography (4D-CT) images of 10 patients with gastric MALT lymphomas were divided into 10 respiratory phases. Further, the 3D-dose was calculated using 3D conformal RT (3D-CRT) and volumetric modulated arc therapy (VMAT) plans based on the average intensity projection (AIP) images. Then, both plans were recalculated according to each phase image. Moreover, the dose distributions in each phase were transferred to the AIP images using deformable image registration. The 4D-dose distribution was calculated by summing the doses of each phase, and it was compared with the dosimetric parameters of the 3D-dose distribution. RESULTS: For 3D-CRT, the D95 and D99 of the 4D-dose in the planning target volume (PTV) were significantly lower than those of the 3D-dose, with mean differences of 0.2 (p=0.009) and 0.1 Gy (p=0.021), respectively. There were no significant differences in the other PTV and organ-at-risk dosimetric parameters of 3D-CRT or in any dosimetric parameters of VMAT between the 3D- and 4D-dose distributions. CONCLUSION: The effect of respiratory motion on the planned 3D-CRT and VMAT dose distributions for gastric MALT lymphoma is minimal and clinically negligible.


Assuntos
Neoplasias Pulmonares , Linfoma de Zona Marginal Tipo Células B , Linfoma não Hodgkin , Radioterapia Conformacional , Radioterapia de Intensidade Modulada , Neoplasias Gástricas , Humanos , Linfoma de Zona Marginal Tipo Células B/diagnóstico por imagem , Linfoma de Zona Marginal Tipo Células B/radioterapia , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia Conformacional/métodos , Radioterapia de Intensidade Modulada/métodos , Neoplasias Pulmonares/radioterapia
11.
Phys Med Biol ; 69(6)2024 Mar 20.
Artigo em Inglês | MEDLINE | ID: mdl-38330494

RESUMO

Modern radiotherapy delivers highly conformal dose distributions to irregularly shaped target volumes while sparing the surrounding normal tissue. Due to the complex planning and delivery techniques, dose verification and validation of the whole treatment workflow by end-to-end tests became much more important and polymer gel dosimeters are one of the few possibilities to capture the delivered dose distribution in 3D. The basic principles and formulations of gel dosimetry and its evaluation methods are described and the available studies validating device-specific geometrical parameters as well as the dose delivery by advanced radiotherapy techniques, such as 3D-CRT/IMRT and stereotactic radiosurgery treatments, the treatment of moving targets, online-adaptive magnetic resonance-guided radiotherapy as well as proton and ion beam treatments, are reviewed. The present status and limitations as well as future challenges of polymer gel dosimetry for the validation of complex radiotherapy techniques are discussed.


Assuntos
Polímeros , Radioterapia Conformacional , Planejamento da Radioterapia Assistida por Computador/métodos , Dosagem Radioterapêutica , Radioterapia Conformacional/métodos , Radiometria/métodos
12.
Sci Rep ; 13(1): 23110, 2024 01 03.
Artigo em Inglês | MEDLINE | ID: mdl-38172237

RESUMO

Radiation therapy is an important tool in the treatment of breast cancer and can play a crucial role in improving patient outcomes. For breast cancer, if the technique has been for a long time the use of 3DCRT, clinicians have seen the management evolve greatly in recent years. Field-in-field and IMRT approaches and more recently dynamic arctherapy are increasingly available. All of these approaches are constantly trying to improve tumour coverage and to preserve organs at risk by minimising the doses delivered to them. If arctherapy allows a considerable reduction of high doses received by healthy tissues, no one can deny that it also leads to an increase of low doses in tissues that would not have received any with other techniques. We propose a hybrid approach combining the robustness of the 3DCRT approach and the high technicality and efficiency of arctherapy. Statistical tests (ANOVA, Wilcoxon, determination coefficient, ROC, etc.) allow us to draw conclusions about the possibility of using the hybrid approach in certain cases (right breast, BMI [Formula: see text], age [Formula: see text], target volume [Formula: see text] cc, etc.). Depending on the breast laterality and patients morphological characteristics, hybridization may prove to be a therapeutic tool of choice in the management of breast cancer in radiotherapy.


Assuntos
Neoplasias da Mama , Radioterapia Conformacional , Radioterapia de Intensidade Modulada , Humanos , Feminino , Neoplasias da Mama/radioterapia , Radioterapia de Intensidade Modulada/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia Conformacional/métodos , Mama , Dosagem Radioterapêutica , Órgãos em Risco
13.
J Cancer Res Clin Oncol ; 150(1): 20, 2024 Jan 20.
Artigo em Inglês | MEDLINE | ID: mdl-38244105

RESUMO

PURPOSE: Concurrent chemoradiation has been the mainstay of treatment for cervix cancer. We aimed to evaluate the non-inferiority of hypofractionated chemoradiation. METHODS: This study was designed as a phase 2, 1:1 randomized, investigator-blinded, controlled, non-inferiority trial and we report the interim results after 50% accrual. Cervical cancer patients with FIGO stages IIA-IIIC were recruited from April 2021 to September 2022. The intervention consisted of 40 Gy of 3D-conformal radiation therapy (RT) in 15 fractions over 3 weeks. In the control group, patients received standard chemoradiation of 45 Gy in 25 fractions over 5 weeks. Both groups received concurrent weekly cisplatin (40 mg/m2). Intravaginal brachytherapy of 28 Gy in 4 weekly fractions was delivered starting 1 week after the end of chemoradiation. The primary outcome was complete clinical response(CCR) at 3 months. Secondary outcomes included acute gastrointestinal (GI), genitourinary(GU), skin, and hematologic toxicities. A p value less than 0.05 was considered significant for analyses. RESULTS: 59 patients were randomized; 30 in the control group and 29 in the intervention group. 20/30 (66.7%) of the patients in the control group and 19/29 (65.5%) in the intervention group achieved a CCR (absolute difference of 0.011, 95% CI - 0.23 to 0.25, p value: 0.13). There was a significantly higher rate of acute grade ≥ 3 GI toxicity in the intervention group (27.6%) compared with the control group (6.7%) (p value 0.032). CONCLUSIONS: Despite an absolute difference of 1.1% in the 3-month CCR, our interim analysis failed to show the non-inferiority of the hypofractionated chemoradiation. Due to the higher GI toxicities, we will continue this trial using intensity-modulated radiation therapy. REGISTRATION NUMBER AND DATE: ClinicalTrials.gov: NCT04831437, 2021.4.1.


Assuntos
Braquiterapia , Radioterapia Conformacional , Neoplasias do Colo do Útero , Feminino , Humanos , Braquiterapia/métodos , Quimiorradioterapia/métodos , Cisplatino/uso terapêutico , Neoplasias do Colo do Útero/tratamento farmacológico , Neoplasias do Colo do Útero/radioterapia
14.
J Appl Clin Med Phys ; 25(3): e14284, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38295191

RESUMO

PURPOSE: External beam radiotherapy is a complex process, involving timely coordination among multiple teams. The aim of this study is to report our experience of establishing a standardized workflow and using quantitative data and metrics to manage the time-to-treatment initiation (TTI). METHODS AND MATERIALS: Starting in 2014, we established a standard process in a radiation oncology-specific electronic medical record system (RO-EMR) for patients receiving external beam radiation therapy in our department, aiming to measure the time interval from simulation to treatment initiation, defined as TTI, for radiation oncology. TTI data were stratified according to the following treatment techniques: three-dimensional (3D) conformal therapy, intensity-modulated radiotherapy (IMRT), and stereotactic body radiotherapy (SBRT). Statistical analysis was performed with the Mann-Whitney test for the respective metrics of aggregate data for the initial period 2012- 2015 (PI) and the later period 2016-2019 (PII). RESULT: Over 8 years, the average annual number of treatments for PI and PII were 1760 and 2357 respectively, with 3D, IMRT, and SBRT treatments accounting for 53, 29, 18% and 44, 34, 22%, respectively, of the treatment techniques. The median TTI for 3D, IMRT, and SBRT for PI and PII were 1, 6, 7, and 1, 5, 7 days, respectively, while the 90th percentile TTI for the three techniques in both periods were 5, 9, 11 and 4, 9, 10 days, respectively. From the aggregate data, the TTI was significantly reduced (p = 0.0004, p < 0.0001, p < 0.0001) from PI to PII for the three treatment techniques. CONCLUSION: Establishing a standardized workflow and frequently measuring TTI resulted in shortening the TTI during the early years (in PI) and maintaining the established TTI in the subsequent years (in PII).


Assuntos
Radiocirurgia , Radioterapia Conformacional , Radioterapia de Intensidade Modulada , Humanos , Planejamento da Radioterapia Assistida por Computador/métodos , Fluxo de Trabalho , Radioterapia Conformacional/métodos , Radioterapia de Intensidade Modulada/métodos , Radiocirurgia/métodos
15.
Strahlenther Onkol ; 200(1): 71-82, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37380796

RESUMO

PURPOSE: The robustness of surface-guided (SG) deep-inspiration breath-hold (DIBH) radiotherapy (RT) for left breast cancer was evaluated by investigating any potential dosimetric effects due to the residual intrafractional motion allowed by the selected beam gating thresholds. The potential reduction of DIBH benefits in terms of organs at risk (OARs) sparing and target coverage was evaluated for conformational (3DCRT) and intensity-modulated radiation therapy (IMRT) techniques. METHODS: A total of 192 fractions of SGRT DIBH left breast 3DCRT treatment for 12 patients were analyzed. For each fraction, the average of the real-time displacement between the isocenter on the daily reference surface and on the live surface ("SGRT shift") during beam-on was evaluated and applied to the original plan isocenter. The dose distribution for the treatment beams with the new isocenter point was then calculated and the total plan dose distribution was obtained by summing the estimated perturbed dose for each fraction. Then, for each patient, the original plan and the perturbed one were compared by means of Wilcoxon test for target coverage and OAR dose-volume histogram (DVH) metrics. A global plan quality score was calculated to assess the overall plan robustness against intrafractional motion of both 3DCRT and IMRT techniques. RESULTS: Target coverage and OAR DVH metrics did not show significant variations between the original and the perturbed plan for the IMRT techniques. 3DCRT plans showed significant variations for the left descending coronary artery (LAD) and the humerus only. However, none of the dose metrics exceeded the mandatory dose constraints for any of the analyzed plans. The global plan quality analysis indicated that both 3DCRT and IMRT techniques were affected by the isocenter shifts in the same way and, generally, the residual isocenter shifts more likely tend to worsen the plan in all cases. CONCLUSION: The DIBH technique proved to be robust against residual intrafractional isocenter shifts allowed by the selected SGRT beam-hold thresholds. Small-volume OARs located near high dose gradients showed significant marginal deteriorations in the perturbed plans with the 3DCRT technique only. Global plan quality was mainly influenced by patient anatomy and treatment beam geometry rather than the technique adopted.


Assuntos
Neoplasias da Mama , Radioterapia Conformacional , Radioterapia de Intensidade Modulada , Neoplasias Unilaterais da Mama , Humanos , Feminino , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/métodos , Suspensão da Respiração , Radioterapia Conformacional/métodos , Neoplasias da Mama/radioterapia , Radioterapia de Intensidade Modulada/métodos , Órgãos em Risco , Neoplasias Unilaterais da Mama/radioterapia
16.
Pract Radiat Oncol ; 14(2): 112-132, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-37977261

RESUMO

PURPOSE: This guideline provides evidence-based recommendations on appropriate indications and techniques for partial breast irradiation (PBI) for patients with early-stage invasive breast cancer and ductal carcinoma in situ. METHODS: ASTRO convened a task force to address 4 key questions focused on the appropriate indications and techniques for PBI as an alternative to whole breast irradiation (WBI) to result in similar rates of ipsilateral breast recurrence (IBR) and toxicity outcomes. Also addressed were aspects related to the technical delivery of PBI, including dose-fractionation regimens, target volumes, and treatment parameters for different PBI techniques. The guideline is based on a systematic review provided by the Agency for Healthcare Research and Quality. Recommendations were created using a predefined consensus-building methodology and system for grading evidence quality and recommendation strength. RESULTS: PBI delivered using 3-dimensional conformal radiation therapy, intensity modulated radiation therapy, multicatheter brachytherapy, and single-entry brachytherapy results in similar IBR as WBI with long-term follow-up. Some patient characteristics and tumor features were underrepresented in the randomized controlled trials, making it difficult to fully define IBR risks for patients with these features. Appropriate dose-fractionation regimens, target volume delineation, and treatment planning parameters for delivery of PBI are outlined. Intraoperative radiation therapy alone is associated with a higher IBR rate compared with WBI. A daily or every-other-day external beam PBI regimen is preferred over twice-daily regimens due to late toxicity concerns. CONCLUSIONS: Based on published data, the ASTRO task force has proposed recommendations to inform best clinical practices on the use of PBI.


Assuntos
Braquiterapia , Neoplasias da Mama , Carcinoma Intraductal não Infiltrante , Radioterapia Conformacional , Estados Unidos , Humanos , Feminino , Neoplasias da Mama/radioterapia , Mama
17.
Head Neck ; 46(2): 239-248, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37933710

RESUMO

BACKGROUND: We evaluated clinical and dosimetric outcomes of radiotherapy using two anterior oblique portals (AOP), to reduce the dose to the bilateral internal carotid arteries (CAs) and pharyngeal constrictor muscle (PCM) during early-stage glottic cancer (ESGC) treatment. METHODS: We identified patients with ESGC who underwent definitive radiotherapy between June 2014 and May 2020. RESULTS: Among the 66 patients, 32 (48%) underwent radiotherapy using AOP, and the remaining underwent typical radiotherapy using parallel opposed lateral portals (POLP). The median follow-up duration was 53 months. No significant differences were observed in the 5-year local failure (0%/9.4%), progression-free survival (90.6%/90.8%), and overall survival (90.6%/91.0%) rates between the two groups. The grade ≥2 acute mucositis incidence rate was significantly lower in the AOP group (44%/85%). Radiotherapy using AOP maintained an adequate dose coverage to the target while markedly reducing the CAs and PCM doses. CONCLUSION: Radiotherapy with AOP resulted in favorable clinical and dosimetric outcomes.


Assuntos
Neoplasias Laríngeas , Radioterapia Conformacional , Radioterapia de Intensidade Modulada , Humanos , Artéria Carótida Interna , Neoplasias Laríngeas/radioterapia , Neoplasias Laríngeas/etiologia , Radioterapia de Intensidade Modulada/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia Conformacional/efeitos adversos , Radioterapia Conformacional/métodos , Músculos , Dosagem Radioterapêutica
18.
Radiol Phys Technol ; 17(1): 143-152, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37930563

RESUMO

This study focused on the dosimetric impact of variations in respiratory motion during lung stereotactic body radiotherapy (SBRT). Dosimetric comparisons between volumetric modulated arc therapy (VMAT) and three-dimensional conformal radiotherapy (3DCRT) were performed using four-dimensional computed tomography (4DCT)-based internal target volumes (ITV). We created retrospective plans for ten patients with lung cancer who underwent SBRT using 3DCRT and VMAT techniques. A Delta4 Phantom + (ScandiDos, Uppsala, Sweden) was used to evaluate the dosimetric robustness of 4DCT-based ITV against variations in respiratory motion during treatment. We analyzed respiratory motion during treatment. Dose-volume histogram parameters were evaluated for the 95% dose (D95%) to the planning target volume (PTV) contoured on CT images obtained under free breathing. The correlations between patient respiratory parameters and dosimetric errors were also evaluated. In the phantom study, the average PTV D95% dose differences for all fractions were - 2.9 ± 4.4% (- 16.0 - 1.2%) and - 2.0 ± 2.8% (- 11.2 - 0.7%) for 3DCRT and VMAT, respectively. The average dose difference was < 3% for both 3DCRT and VMAT; however, in 5 out of 42 fractions in 3DCRT, the difference in PTV D95% was > 10%. Dosimetric errors were correlated with respiratory amplitude and velocity, and differences in respiratory amplitude between 4DCT and treatment days were the main factors causing dosimetric errors. The overall average dose error of the PTV D95% was small; however, both 3DCRT and VMAT cases exceeding 10% error were observed. Larger errors occurred with amplitude variation or baseline drift, indicating limited robustness of 4DCT-based ITV.


Assuntos
Neoplasias Pulmonares , Radiocirurgia , Radioterapia Conformacional , Radioterapia de Intensidade Modulada , Humanos , Radiocirurgia/métodos , Radioterapia de Intensidade Modulada/métodos , Tomografia Computadorizada Quadridimensional/métodos , Estudos Retrospectivos , Planejamento da Radioterapia Assistida por Computador/métodos , Neoplasias Pulmonares/diagnóstico por imagem , Neoplasias Pulmonares/radioterapia , Neoplasias Pulmonares/cirurgia , Pulmão , Dosagem Radioterapêutica
19.
Cancer Res Treat ; 56(1): 1-17, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37654111

RESUMO

Radiotherapy (RT) is a fundamental modality in treatment of cervical cancer. With advancement of technology, conventional RT used for external beam radiotherapy (EBRT) for over half a century has been rapidly replaced with intensity-modulated radiation therapy (IMRT) especially during the last decade. This newer technique is able to differentiate the intensity of radiation within the same field, thus reduces the inevitable exposure of radiation to normal organs and enables better dose delivery to tumors. Recently, the American Society for Radiation Oncology has released a guideline for RT in cervical cancer. Although a section of the guideline recommends IMRT for the purpose of toxicity reduction, a thorough review of the literature is necessary to understand the current status of IMRT in cervical cancer. This narrative review updates the recent high-level evidences regarding the efficacy and toxicity of IMRT and provides a better understanding of the most innovative techniques currently available for EBRT enabled by IMRT.


Assuntos
Radioterapia Conformacional , Radioterapia de Intensidade Modulada , Neoplasias do Colo do Útero , Feminino , Humanos , Radioterapia de Intensidade Modulada/efeitos adversos , Radioterapia de Intensidade Modulada/métodos , Neoplasias do Colo do Útero/patologia , Dosagem Radioterapêutica , Radioterapia Conformacional/métodos
20.
Prostate Cancer Prostatic Dis ; 27(1): 95-102, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36849728

RESUMO

BACKGROUND: While moderately hypofractionated radiotherapy (MHRT) for prostate cancer (PC) is commonly delivered by intensity modulated radiation therapy, IMRT has not been prospectively compared to three-dimensional conformal radiotherapy (3D-CRT) in this context. We conducted a secondary analysis of the phase III RTOG 0415 trial comparing survival and toxicity outcomes for low-risk PC following MHRT with IMRT versus 3D-CRT. METHODS: RTOG 0415 was a phase III, non-inferiority trial randomizing low-risk PC patients to either MHRT or conventionally fractionated radiation with stratification by RT technique. A secondary analysis for differences in overall survival (OS), biochemical recurrence free survival (BRFS), or toxicity by EPIC scores and Common Terminology Criteria for Adverse Events (CTCAE) was performed. RESULTS: 1079 patients received the allocated intervention with a median follow up of 5.8 years. 79.1% of patients were treated with IMRT and radiation technique was balanced between arms. Across all patients, RT technique was not associated with significant differences in BRFS, OS, or rates of acute and late toxicities. For patients completing MHRT, there was a difference in the late GU toxicity distribution between 3D-CRT and IMRT but no difference in late grade 2 or greater GU or GI toxicity. Stratifying patients by RT technique and fractionation, no significant differences were observed in the minimal clinically important difference (MCID) in EPIC urinary and bowel scores following RT. CONCLUSIONS: RT technique did not impact clinical outcomes following MHRT for low-risk PC. Despite different late GU toxicity distributions in patients treated with MHRT by IMRT or 3D-CRT, there was no difference in late Grade 2 or greater GU or GI toxicity or patient reported toxicity. Increases in late GU and GI toxicity following MHRT compared to CFRT, as demonstrated in the initial publication of RTOG 0415, do not appear related to a 3D-CRT treatment technique.


Assuntos
Neoplasias da Próstata , Radioterapia Conformacional , Radioterapia de Intensidade Modulada , Masculino , Humanos , Radioterapia Conformacional/efeitos adversos , Radioterapia Conformacional/métodos , Radioterapia de Intensidade Modulada/efeitos adversos , Radioterapia de Intensidade Modulada/métodos , Risco , Dosagem Radioterapêutica
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...